CKO-LED-775-B-A
Amber Light Bar 1500mm Bolt Mounted

£412.86 ex VAT

Light Colour: Amber
Lens: Clear
Fixing: Bolt Bracket
Approval: ECE R10/R65 Approved
Voltage: 12-24V
IP Rating: IP67
LEDs: 252
Patterns: 27 Selectable Flash Patterns
Additional: Cable with switch included
Dimensions: 1500mm x 100mm x 45mm

Tough polycarbonate lens with UV resistance
Aluminium base
Reverse polarity protection
Clear Lens
-30?C to +60?C operating temperature

Wiring
Red: Power
Black: Ground
Yellow: Pattern Programming / Synchronisation or alternative flash
White: Dimming – connect to ground to activate
Grey: Cruise mode – connect to ground to activate

(1) Pattern Selection – Apply Yellow to black wire
Less than 1 second for next pattern
3 to 5 seconds for previous pattern
6 to 9 seconds to reset back to pattern 1
(2) Synchronisation: when ungrouped, connect the yellow wire of all strobes together to achieve synchronisation.
(3) Simultaneous or Alternating Flash + Reset group – Apply Yellow to Black wire
Simultaneous or Alternating Flash
Step 1: Set Group A: connect yellow wire of all Group A’s head together, apply to black wire 16-19 seconds, Group A is now set. (Group A will not light up at this time, which is the default status.)
Step 2: Set Group B: connect yellow wire of all Group B’s head together, apply to black wire 21-24 seconds, Group B is now set. (Group B will light up and can change flash pattern after power off and on; and it will follow Group B?s flash pattern when connect the yellow wire of Group A and Group B together.)
Step 3: use Group A/B: connect yellow wire of Group A and Group B together, apply it to black wire 11-14 seconds for Alternating flash; apply it to black wire 11-14 seconds again back to simultaneous flash. (If the time is exceed 14 seconds, all heads will NOT light up, repeat steps 1 & 2.)
Resetting groups:
Connect yellow wire of Group A and Group B’s strobes together, apply to black wire 21-24 seconds, then power off and on, head light up, means resetting was successful.
(Then can use individually or can be grouped)

Flash Pattern Information
Tap yellow wire to black for less than 1 second for next pattern, 1-3 seconds for previous pattern or over 5 seconds to return to the first pattern
1. Single R65
2. Single Slow
3. Double R65/SAE
4. Double Slow
5. Triple
6. Quad Fast R65
7. Quad Slow
8. Octa Fast
9. Octa Slow
10. Twelve
11. Sixteen
12. Single – Split
13. Double – Split
14. Quad – Split
15. Octa – Split
16. Single – Split Accelerate
17. Double – Split Accelerate
18. SOS
19. Cycle (1,8,3,9,4,18)
20. Cycle (2,7,9,11,14,16)
21. Steady On